Level Measurement

TwitterFacebookLinkedInGoogleDeliciousRSS

Home | Hazardous Location Transmitters | 627 Series Intrinsically Safe Submersible Liquid Level | Product Specifications

 

627 Series Intrinsically Safe Submersible Liquid Level Transmitters
Product Specifications

 

SPECIFICATIONS
Output signal 4 mA to 20 mA, 2-wire
Pressure ranges 0 inH2O to 50 inH2O through 0 psig to 350 psig
Accuracy ±0.25 % full scale (BFSL); optional ±0.125% full scale (BFSL), for ranges
≥ 150 inH2O (Includes the effects of non-linearity, hysteresis, non-repeatability,
zero point and full scale errors)
Stability ≤ ±0.2% full scale for 1 year, non-accumulating
Response time ≤1 ms (between 10% and 90% full scale)
Durability >100,000,000 full scale cycles
Temperature ranges Compensated 32 °F to 122 °F (0 °C to 50 °C)
Zero effect is ±0.011% full scale/ °F within compensated range
Span effect is ±0.011% full scale/ °F within compensated range
Media 15 °F to 175 °F (-10 °C to 60 °C)
Ambient 15 °F to 122 °F (-10 °C to 50 °C)
Storage -30 °F to 175 °F (-34 °C to 60 °C)
Power requirement* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire)
Load limitations ≤ (VPower-10)/0.020 Amp-(0.043 Ω x length of cable in feet)
Proof pressure 2 times range
Burst pressure 3 times range
Measuring element Diaphragm and cap: 316 stainless steel
17-4PH stainless steel for 0 psig to 350 psig
Cable: Polyurethane, optional FEP
Connection 316 stainless steel
Housing material 316 stainless steel
Environmental rating IP68
Electromagnetic rating CE compliant to EMC norm EN 61326:1997/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, over-voltage and short circuit protected
Weight Approximately 7 oz. with standard nosecone - cable extra

         * Unregulated

NOSHOK, INC. 1010 W. Bagley Road | Berea, OH 44017 | Ph 440.243.0888 | Fax 440.243.3472 | Webmaster | Site Map
©2017 NOSHOK. ALL RIGHTS RESERVED.